Industrial facility operated by Genesis Industrial Solutions Ltd

Established 2014 · Trinidad & the Caribbean

Industrial Maintenance & Engineering Solutions

Genesis Industrial Solutions Ltd — specialists in transformer oil degassing, transformer dehydration, transformer parts supply, and precision industrial maintenance across Trinidad and the Caribbean since 2014.

Our Services

Comprehensive industrial maintenance and engineering solutions tailored to your operational needs.

CAT III Vibration Testing

Precision vibration analysis and testing to detect mechanical faults, imbalance, misalignment, and bearing defects before they cause costly downtime.

Infrared Thermography

Non-contact thermal imaging inspections to identify electrical hotspots, insulation failures, and overheating components in real time.

High Voltage (HV) Testing

Specialized high voltage testing services performed by Mr. Alvin Ramsaran, HV Specialist of ARelec Engineering. Ensuring electrical equipment integrity, safety compliance, and reliable performance.

3D Laser Alignment

High-accuracy 3D laser shaft alignment services for rotating equipment, reducing vibration, bearing wear, and energy consumption.

Mechanical Maintenance

Expert repair and overhaul of pumps, gearboxes, compressors, valves, and generators. Full plant equipment maintenance programs available.

Metal Coatings

Protective and industrial metal coating applications to extend equipment life, resist corrosion, and maintain operational integrity.

Failure Analysis

Specialized Mechanical Systems Equipment Failure Analysis Mode reporting to identify root causes and prevent recurrence.

Asset Management

Systematic management of physical assets throughout their lifecycle — from condition assessment and criticality ranking to maintenance strategy development and performance tracking.

Maintenance Consultancy

Backed by over 20 years of hands-on experience in maintenance, planning, and reliability, we provide expert consultancy to optimize your maintenance programs.

Power Quality Monitoring

Comprehensive three-phase power quality studies using the Fluke 1770 Series analyzers. We capture over 500 parameters — voltage dips and swells, harmonics up to 30 kHz, high-speed transients up to 8 kV, flicker, unbalance, and energy loss.

Acoustic Imaging

Ultrasonic acoustic imaging across 2 kHz–100 kHz to detect and locate faults invisible to the eye. Detects: partial discharge in switchgear and transformers, compressed air and gas leaks, steam trap failures, mechanical bearing defects, vacuum leaks, and electrical arcing — all while equipment remains live and in service.

Vibration Analysis

Did You Know?

Most Faults Give Early Warning

The majority of rotating machinery faults — including bearing defects, imbalance, misalignment, looseness, and resonance — produce detectable vibration signatures well before catastrophic failure occurs. A bearing defect, for example, can be detected weeks or even months in advance when the right measurement techniques are applied. This means that with a structured vibration monitoring program, most unplanned shutdowns are entirely preventable.

Vibration Reveals What Eyes Cannot See

Vibration analysis is one of the most powerful predictive maintenance technologies available. A single vibration spectrum can simultaneously reveal imbalance, misalignment, looseness, bearing wear, gear mesh problems, and resonance — all without stopping the machine or opening it up.

Recommendation from Mobius Institute

Establish a regular vibration monitoring route on all critical rotating assets — motors, pumps, fans, gearboxes, and compressors. Measurements should be taken at consistent intervals (monthly for critical machines, quarterly for general plant) and trended over time.

Introduction to Vibration Analysis — Jason Tranter, Mobius Institute
Watch on YouTube ↗
Introduction to Vibration Analysis — Jason Tranter, Mobius Institute
Mobius Institute YouTube
Introduction to Shaft Alignment — PRUFTECHNIK
Watch on YouTube ↗
Introduction to Shaft Alignment — PRUFTECHNIK
PRUFTECHNIK YouTube

Laser Shaft Alignment

Did You Know?

Misalignment is the #1 Cause of Bearing Failure

Shaft misalignment is one of the leading root causes of premature bearing and seal failure in rotating machinery. Even a small angular or parallel offset between a motor and pump shaft creates cyclic bending forces that dramatically shorten bearing life — often reducing it by 50% or more.

Laser Alignment Pays for Itself Immediately

Precision laser shaft alignment consistently delivers measurable returns: reduced energy consumption (studies show 2–10% energy savings on aligned machines), extended bearing and seal life, reduced vibration levels, fewer unplanned shutdowns, and lower maintenance costs over the asset lifecycle.

Recommendation from Mobius Institute

Perform precision laser shaft alignment on every motor-driven machine after installation, after any maintenance that involves removing or replacing a motor or driven equipment, and as part of any planned shutdown.

Recommendation from Mobius Institute

Perform precision laser shaft alignment on every motor-driven machine after installation, after any maintenance that involves removing or replacing a motor or driven equipment, and as part of any planned shutdown. Never assume a machine is aligned because it was aligned before — thermal growth, pipe strain, and foundation settling all cause alignment to drift over time.

Acoustic Imaging

Did You Know?

Acoustic imaging uses an array of microphones to visualise sound — converting ultrasonic frequencies into a colour-coded heatmap overlaid on a live camera image. Our Fortic Acoustic Camera operates across 2 kHz–100 kHz, detecting faults that are completely invisible to thermal cameras, vibration sensors, or the naked eye.

Fortic Acoustic Camera in use during an industrial inspection by GISL
2 kHz – 100 kHz
Acoustic Imaging

What Acoustic Imaging Detects

Partial Discharge (PD)
Compressed Air & Gas Leaks
Steam Trap Failures
Bearing & Gear Defects
Electrical Arcing & Corona
Vacuum Leaks
FLIR Si2 Acoustic Imaging Camera — Air Leak, Mechanical Fault & Partial Discharge Detection
Acoustic Imaging in Action
Watch on YouTube ↗

Partial Discharge Detection

Partial discharge (PD) in high-voltage switchgear, transformers, and cable terminations emits ultrasonic energy in the 20–100 kHz range. Acoustic imaging pinpoints the exact source of PD activity on live equipment — without contact, without shutdown, and without risk to personnel. Early PD detection prevents insulation breakdown, arc flash events, and catastrophic transformer failure.

Compressed Air & Gas Leak Detection

Compressed air leaks are one of the largest sources of energy waste in industrial plants — studies estimate 20–30% of compressed air is lost to leaks. The Fortic camera instantly locates leaks in pipework, fittings, valves, and pneumatic systems from a safe distance, even in noisy plant environments where traditional ultrasonic probes struggle.

Steam Trap & Valve Diagnostics

Failed-open steam traps waste significant energy and increase carbon emissions. Acoustic imaging identifies both failed-open and failed-closed steam traps, as well as passing valves and internal bypass leaks — all without insulation removal or contact with hot surfaces.

Mechanical Bearing & Gear Defects

Early-stage bearing defects, gear mesh anomalies, and lubrication failures produce characteristic high-frequency acoustic signatures well before they appear in standard vibration spectra. Acoustic imaging adds a complementary detection layer — particularly useful on slow-speed machinery where vibration analysis has limited sensitivity.

Electrical Arcing & Corona

Arcing, corona discharge, and tracking on electrical busbars, insulators, and cable joints produce intense ultrasonic emissions. The Fortic camera locates these sources on live MV/HV equipment from a safe standoff distance, enabling targeted maintenance before a fault escalates to an outage or fire.

Vacuum Leak Detection

Vacuum systems in process plants, laboratories, and power generation equipment are susceptible to leaks that degrade process efficiency. Acoustic imaging detects the turbulent flow signature of vacuum leaks quickly and accurately, even in areas with background noise.

Acoustic Imaging

All inspections are performed on live, in-service equipment — no shutdown required.

Specialized Department
IQ Transformer Labs — Genesis Industrial Solutions Ltd

IQ Transformer Lab

A dedicated department specializing in transformer oil degassing, transformer dehydration, transformer parts supply, and comprehensive insulating oil laboratory diagnostics.

Visit iqtlab.co

Insulating Oil (Transformer Oil) Laboratory Testing

We conduct insulating oil (transformer oil) laboratory testing for:

DGA (Dissolved Gas Analysis)
IFT (Interfacial Tension)
BDV (Breakdown Voltage)
TAN (Total Acid Number)
Tan Delta
Moisture
Furan
Color
ISO 17025 Standards for Lab Diagnostics
Doble and SDMyers Trained

Already a Customer! Click The link www.iqtlab.co to login and view your insulating oil report

IQ Transformer Lab
Watch on YouTube ↗
IQ Transformer Lab
Did You Know?

The moisture content of the liquid insulation (the oil) is only a partial indicator of the amount of moisture in a transformer. The paper insulation has 100 times or more affinity for moisture compared to the oil. The paper's lifespan is cut in half every time the moisture content doubles.

This is important because the paper is the primary limiting factor in the life of a transformer. Moisture in the paper will accelerate the oxidation process — compromising the paper, weakening the unit's efficiency, decreasing dielectric strength, increasing the risk of flashover, and eventually leading to failure. The paper's lifespan is cut in half every time the moisture content doubles. And every year of delay in fixing the problem chips away at approximately two years of reliable service.

Recommendation: It is best practice to filter your transformer oil every 2 years to maintain dielectric strength, remove moisture and contaminants, and extend the life of both the oil and the paper insulation.

"The life of the paper is the life of the transformer."

Ref: SDMyers

Our Process

How Do We Dry Out a Transformer?

Moisture removal is critical to extending transformer life. Our automated transformer oil filtration system removes moisture, gases, and particulates from insulating oil — restoring dielectric strength and protecting the paper insulation that determines the transformer's lifespan. Watch the video to see our automated process in action with real time testing of the liquid.

Demonstrated using our automated transformer oil degassing and filtration system.
How Do We Dry Out a Transformer?
Watch on YouTube ↗
Transformer Dehydration — How Do We Dry Out a Transformer?

Transformer Repair

Oil extraction and refilling, part replacement, torquing of bushings, elbows and components, resealing, and nitrogen reblanketing.

Transformer Parts Supply

Supply of transformer parts and components — bushings, elbows, wells, fuses, connections, and all transformer hardware.

Insulating Oil Failure Analysis

Comprehensive insulating oil failure analysis mode reporting for accurate diagnostics and compliance.

Transformer Oil Degassing & Dehydration

Automated transformer oil degassing and dehydration services — removing dissolved gases and moisture to restore dielectric strength and extend transformer life.

Power Generator Sales & Supply

Sales and supply of power generators for industrial, commercial, and critical infrastructure applications.

About Genesis Industrial Solutions Ltd

Precision. Reliability. Excellence.

Founded in 2014, Genesis Industrial Solutions Ltd (GISL) is a Trinidad-based industrial services company delivering high-quality maintenance, testing, and engineering solutions to the energy, utilities, and manufacturing sectors. Our team of certified technicians and engineers brings decades of combined experience to every project, ensuring reliability, safety, and operational excellence. We are committed to minimizing downtime and maximizing the performance of your critical assets.

2014

Established

11+

Specialized Services

Energy, Utilities, Manufacturing

Industries Served

Contact Us

Reach out during business hours or send us a message anytime.

Business Hours

Monday – Friday: 8:00 AM – 4:00 PM

After hours? Send a WhatsApp message or call the number above.

IQ Transformer Lab

iqtlab.co

HV Testing Partner

HV testing performed by Mr. Alvin Ramsaran, HV Specialist — ARelec Engineering

areleceng.com

Send Us a Message